Buildings and Construction
15.16.020
Amendments and Additions
15.16.020 Amendments and Additions:

The following sections of the IPC, as adopted by Section 15.16.010, are amended as follows:

A. Amend Section 101.1 Title, of the IPC by replacing “[NAME OF JURISDICTION]” with “City of Shawnee, Kansas”.

B Amend by omitting Sections 103, 104, 105, 106, 108, 109, and 110 of the IPC, in their entirety, and amend by adding a new Section 103 ADMINISTRATIVE PROVISIONS, which reads:

SECTION 103 ADMINISTRATIVE PROVISIONS

The Administrative Provisions of the 2012 International Building Code, Chapter 1, in its entirety, and as modified by the Shawnee Municipal Code, along with Sections 101, 102 and 107 of the IPC, shall govern all matters within the scope of this code.

C. Amend by omitting Section 305.6.1 Sewer depth., of the IPC, and amend by adding a new Section 305.6.1 Sewer depth., which reads:

Section 305.4.1 Sewer depth.
Building sewers that connect to private sewage disposal systems shall comply with the Johnson County Sanitary Code, adopted by Johnson County, Kansas. Building sewer pipe connecting to the public sewer shall comply with the regulations of the Johnson County Wastewater District.

D. Amend the IPC by adding a new Section 410.3 Substitution., which reads:

410.3 Substitution. The Building Official is allowed to accept equivalent means for providing drinking water besides requiring drinking fountains, such as free bottled water, or cleaning equipment that can be used without a service sink.

E. Amend by omitting Section 703.5 Cleanouts on building sewers., of the IPC, and amend by adding a new Section 703.5 Cleanouts on building sewers., which reads:

703.5 Cleanouts on building sewers. Cleanouts on building sewers shall be located as required by the appropriate authority having jurisdiction.

F. Amend by omitting Section 708.3.2 Building sewers., of the IPC, and amend by adding a new Section 708.3.2 Building sewers., which reads:

708.3.2 Building sewers. Cleanouts on building sewers shall be provided and located as required by the appropriate authority having jurisdiction.

G. Amend by omitting Section 1003 INTERCEPTORS AND SEPARATORS, of the IPC, IN ITS ENTIRETY, and amend by adding a new Section 1003 INTERCEPTORS AND SEPARATORS, which reads:

1003 INTERCEPTORS AND SEPARATORS

1003.1 Where required. Interceptors and separators shall be provided, installed, inspected, and maintained as required by the appropriate authority having jurisdiction.

H. Amend Section 904.1 Roof extension. of the IPC by replacing “[NUMBER]” with 6. (Ord. 2903, 2008; Ord. 2756, 2005)

(Ord. 3047, 2012 )